產(chǎn)品品牌:美國FLIR
產(chǎn)品型號:FLIR A310 ex
范圍:–20 to +120°C (–4 to +248°F) 0 to +350°C (+32 to +662°F)
產(chǎn)品品牌:美國FLIR
產(chǎn)品型號:FLIR A310 ex
范圍:–20 to +120°C (–4 to +248°F) 0 to +350°C (+32 to +662°F)
Use the power of thermal imaging in hazardous locations.
Explosive atmospheres need to be protected from ignition sources by selecting equipment and protective systems which meet the requirements of the ATEX Product Regulations or similar regulations.
FLIR A310 ex is an ATEX compliant solution, with a thermal imaging camera mounted in an enclosure, making it possible to monitor critical and other valuable assets also in explosive atmospheres. Process monitoring, quality control and fire detection in potentially explosive locations are typical applications for the A310 ex.
Learn more about the FLIR A310, the thermal imaging camera inside FLIR A310 ex.
Prevents any explosion transmission from the inside of the enclosure to the outside.
The FLIR A310 ex is IP67 rated. Ideal to install in dusty environments.
The integrated controller features several digital I/O channels and sensors for temperature, humidity and pressure. Among other functions, the I/O channels enable the user to switch on/off the camera and the heater via remote control. The access is accomplished through an integrated web interface or Modbus TCP/IP.
The integrated controller is equipped with 2 fiber optic and 2 Ethernet parts. This enables a flexible network integration in star or ring topologies.
FLIR A310 ex comes with a heater which effectively prevents fogging and freezing of the protection window.
FLIR A310 ex is lightweight and the entire system is delivered ready for use.
The FLIR A310 ex is ATEX certified. It can be installed in classification zones 1, 2, 21, 22.
The certification comprises the whole system which includes the enclosure as well as all components inside, such as the thermal imaging camera, heater and integrated controller.
Learn more about the FLIR A310, the thermal imaging camera inside FLIR A310 ex.
General Data | |
---|---|
Ambient temperature range for operation | –20°C to +40°C (-4°F to 104°F) |
Protection class | IP67 |
Weight | 6.7 kg (without camera and lens) |
Empty volume | 5.06 l |
External dimensions (without sun shield) | D = 170 mm, L = 408 mm |
Housing material / Surface | Nickel-plated aluminium / Powder coated |
Protection window | Germanium, double-sided AR Coated, externally with additional hard-carbon layer |
Maximum power of the additional heater | 16 W |
Operating voltage | 24 V DC |
Maximum electric connection power | 60 W |
Power cable / Power cable configuration | Helukabel 37264 / Pigtail |
Length of power cable | 4 m (13 ft.) |
Integrated controller | 4-port switch with 2 × fiber-optic LC 100Base-FX or 2 × RJ45(10/100) up-links, ring-topology support for reduced cabling effort, 2 × internal temperature sensors, air humidity and pressure sensor, digital output module controllable via Modbus TCP/IP or web interface to enable turning the heater on/off |
Ethernet medium | Multi-mode breakout fiber AT-V(ZN)Y(ZN)Y 4G50/125 OM2 |
Length of Ethernet cable | 4 m (13 ft.) |
Ethernet, configuration | Pigtail with FC-connector |
Explosion protection-specific data | |
For use in EX zone | 1, 2, 21, and 22 |
Ignition protection category | Flame-proof enclosure “d” |
Maximum surface temperature (according to temperature class T6) | Maximum 85°C |
ATEX certification (version -AXC) | EX-Protection Gas: II 2G Ex d IIC T6 Gb, EX-Protection Dust: II 2D Ex tb IIC T85° Db |
Verification certificate | ZELM 12 ATEX 0485 X |
Imaging and optical data | |
IR resolution | 320 × 240 pixels |
Thermal sensitivity/NETD | < 0.05°C @ +30°C (+86°F) / 50 mK |
Field of view (FOV) / Focal length | 25° × 18.8° with 18 mm (0.7 in.) lens or 45° × 33.8° with 9.66 mm (0.38 in.) lens |
Minimum focus distance | 0.4 m (1.31 ft.) |
Spatial resolution (IFOV) | 1.36 mrad with 25° lens or 2.59 mrad with 45° lens |
Lens identification | Automatic |
F-number | 1.3 |
Image frequency | 30 Hz |
Focus | Automatic or manual (built in motor) |
Zoom | 1–8× continuous, digital, interpolating zooming on images |
Detector data | |
Detector type | Focal Plane Array (FPA), uncooled microbolometer |
Spectral range | 7.5–13 μm |
Detector pitch | 25 μm |
Detector time constant | Typical 12 ms |
Measurement | |
Object temperature range | –20 to +120°C (–4 to +248°F) 0 to +350°C (+32 to +662°F) |
Accuracy | ±2°C (±3.6°F) or ±2% of reading |
Measurement analysis | |
Spotmeter | 10 |
Area | 10 boxes with max./min./average/position |
Isotherm | 1 with above/below/interval |
Measurement option | Measurement Mask Filter Schedule response: File sending (ftp), email (SMTP) |
Difference temperature | Delta temperature between measurement functions or reference temperature |
Reference temperature | Manually set or captured from any measurement function |
Atmospheric transmission correction | Automatic, based on inputs for distance, atmospheric temperature and relative humidity |
Optics transmission correction | Automatic, based on signals from internal sensors |
Emissivity correction | Variable from 0.01 to 1.0 |
Reflected apparent temperature correction | Automatic, based on input of reflected temperature |
External optics/windows correction | Automatic, based on input of optics/window transmission and temperature |
Measurement corrections | Global and individual object parameters |
Alarm | |
Alarm functions | 6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timer |
Alarm output | Digital Out, log, store image, file sending (ftp), email (SMTP), notification |
Set-up | |
Color palettes | Color palettes (BW, BW inv, Iron, Rain) |
Set-up commands | Date/time, Temperature°C/°F |
Storage of images | |
Storage media | Built-in memory for image storage |
File formats | Standard JPEG, 16-bit measurement data included |
Ethernet | |
Ethernet | Control, result and image |
Ethernet, type / standard | 100 Mbps / IEEE 802.3 |
Ethernet, configuration | Pigtail with FC-connector (fiber) |
Ethernet, communication | TCP/IP socket-based FLIR proprietary |
Ethernet, video streaming | MPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5 |
Ethernet, image streaming | 16-bit 320 × 240 pixels @ 7-8 Hz - Radiometric |
Ethernet, protocols | Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP |
Shipping information | |
Infrared camera with lens, in explosion-proof housing, cardboard box, Printed documentation, User documentation CD-ROM, Utility CD-ROM |